Cardiology · CMS status A
93293
Pacemaker interrogation in-person
Pacemaker interrogation, in-person, single, dual, or multiple-lead system.
Work RVU
0.45
2026 Medicare pays
$29.39
National GPCI · non-facility · CF $33.4009
RVU anatomyWork 0.45 + Practice 0.39 + Malpractice 0.04 = 0.88 total
Work (your effort)Practice expenseMalpractice
When to use it
Face-to-face pacemaker check.
Full guidance
Once per 90 days per pacemaker for routine care.
Documentation checklist
- ✓Device type and serial number.
- ✓Battery, lead impedance, capture, sensing.
- ✓Counters and arrhythmia log.
- ✓Any reprogramming.
Common pitfalls
- !Use 93294 for ICDs, 93295 for ICD-CRT. Wrong device class = denial.
- !Frequency limits — routine remote is 93294 vs in-person 93293; don't double up in the same 90 days.
Common ICD-10 pairings
Z95.0I44.2
Educational reference, not billing or legal advice. Verify against your payer contracts and your compliance team before submission.